Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste may utilize in this gear? A: This gear to medical waste, pet animal, Municipal waste, reside waste. Prohibit any volatile and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Average Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour), not indicate any waste material.
Clover incinerator utilize time daily to 24 hours. Between every feed/combustion time, you will find approximately 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time daily is about 16 hours. The life span of incinerator between 5-10 year according to use.
Ordinarily, we proposal little lab, little clinic use capability under 20 kgs per hour. If incinerator use in hospital, then please compute the waste output around 2kgs per people per day. If there are 200 sickbed at the clinic, that’s mean you need one incinerator capability around 400kgs daily, change to power per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs each hour incinerator. *The best way to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We supply all documents and incinerators easy to installation and operation. Customer can send people visit our factory to learn installation and operation. Generally, we don’t send engineer to local website if not ask. The dispatch cost is additional according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The next combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control manner is common control case. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, utilize situation.
One individual can service 02 unit incinerators. The staff should have fundamental electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to safeguard worker self with essential protection element.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |