Basic Info.
Additional Info.
Product Description
It is being recently issued an ordinance by the Ministry of Environment to construct incineration plants at the metropolitans which generate over 10.000kg of medical waste per day. And this execution is going to start at the start of the calendar year 2014. Our aim is to build a Medical Waste Incineration Plant in among the metropolitan cities in Turkey. We’ve been preparing for the tenders which are likely to be held soon by the Metropolitan Municipality. We would like to cooperate with a supplier/contractor for building an incineration plant. Would you be able to inform if you invent incineration plants, even if yes kindly advise in which part of the planet you’d worked (constructed incineration plants).
Could you also please inform us regarding the following issues: – Can it be possible to achieve an incineration temperature of 1.100° C inside the systems which you’ve been inventing? (This is only one of those criteria for its incineration plants in line with the regulations in Turkey). – Is it possible to create power and how? – If it’s likely to create electricity inside the system, what is the kwh quantity of power per ton of waste incinerated? – What’s the time for building the plant? How long would it mobile medical incinerators, mobile pet cremation, mobile garbage incinerator, posco krakow incineration plant, post-animal incinerator fuel, choose for building a plant and would it rely on the plant capacity like 1.000kg/hr or 2.000kg/hr? – What’s the water intake per incinerated ton? And if there is electricity generation inside the machine, what is the quantity of water consumption per ton for generating 1 kwh of energy? – Do the crops which you invent have gas cleaning and filtering methods? If already contained or could be added, would you be able to advise your costs involving the gas cleaning and filtering methods? – Would there be a change in the costs if power production could be added to the machine? If so, would you please notify your costs according to this? We anticipate your cooperation. Thank you in advance for your fastest possible response. (Turkey)
Que valor tiene un incinerador PARA quemar droga.
– Que consumo de energí A tiene? ? ? – Cuanta contaminació N genera a la ATMó Sfera.
Saludos y quedo atento. (Chile)
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |