Basic Info.
Additional Info.
Product Description
Q: What is kind of waste can utilize in this equipment? A: This equipment for pet creature, medical waste, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid gas and waste waste. GB18484-2001.
Q: Treatment ability A: Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion time, there are approximately 0.5-1 hours cooling time plus time to get feeding waste. Actual combustion time daily is around 16 hours. The life of incinerator between 5-10 year according to utilize.
Ordinarily, we proposal customer purchase crematory according to animal size. For small creature, cats, birds suit for small scale crematory (Model YD-15C/20C/30C). For other big creatures, suit for version A1200, A1500, A2400, A4000.
Q: Meeting and Testing A: We provide all documents and incinerators easy to setup and functionality. Client can send individuals visit our factory to find out operation and installation. Normally, waste scale cost, waste to power sprinklers, incinerator capacity of 40 kg/hr, wat is the capacity of burner to the incinerator of 100kg/hr, water dusti filters, We do not send engineer to neighborhood website if not ask. The dispatch cost is extra according to order.
Q: Combustion Temperature A: The very first combustion chamber: 800-1000 centi level. The next combustion chamber: 1000-1200 centi level. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD per year maintenance according version, utilize situation.
One individual can service 02 unit incinerators. The team should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance consumer guider, and understand risk of waste to safeguard worker self with essential protection element.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |