Q: What’s kind of waste can utilize within this gear? A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid gas and waste waste. GB18484-2001.
Q: Remedy capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg a hour), not indicate any waste material. The animal/pet combustion speed around 2/3 of ordinary power.
Clover incinerator utilize time per day up to 24 hours. Between every feed/combustion time, you will find approximately 0.5-1 hours cooling time plus time for feeding squander. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to utilize.
Generally, we proposal small lab, small clinic usage capability under 20 kgs per hour. If incinerator use in hospital, please calculate the waste output around 2kgs per individuals every day. If there are 200 sickbed in the hospital, that’s imply you need one incinerator capability around 400kgs every day, switch to power per hour is approximately 30-40 kgs per hour. According the performance time every day, waste material, funding, growth, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Meeting and Testing A: We supply all files and incinerators easy to installation and operation. Client can send individuals visit our factory to learn operation and installation. Generally, We do not send engineer to neighborhood website or even request. The dispatch price is additional according to order. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control manner is common control case. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation price according to fuel consumption rate and power/staff, etc.
Annual approximately $500-$1000USD per year maintenance according version, utilize situation.
One individual can service 02 unit incinerators. Hospital incinerator manufacturers, incinerator burners, incinerator diesel burn, incinerator manufacturer china, incinerator medical waste maker, incinerator suppliers, The staff must have fundamental electrician comprehension to operate/inspect/maintaince incinerator/burner/blower according to surgery user guider, and know risk of medical waste to protect worker self with essential security component.
Q: The Residency period in combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
Control Mode | PLC | PLC | PLC | PLC | PLC |
Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
Feed Mode | Manual | Manual | Manual | Manual | Manual |
Voltage | 220V | 220V | 220V | 220V | 220V |
Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
Temperature Protection | Yes | Yes | Yes | Yes | Yes |
Oil Tank | 100L | 100L | 100L | 100L | 200L |
Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |